GMH Engineering

navigation bar
Data Brick
Data Brick

This information is available for download in PDF file format in the Literature and Reference Center

The DataBRICK II meets or exceeds all of S.A.E. J211 Specifications

    GENERAL

      Sample Rate (scan rate for all active channels)
      • High Speed 850 - 12,800 Hz
      • Low Speed 2.5 hr/sample - 1000 Hz
      * When using low speed, up to three different sample rates may be used simultaneously.
      Sample Rate Time Base
      • Accuracy ± 100 ppm
      • Drift ± 5 ppm/year
      Data Memory 524,218 data points
      Analog Input Channels 8 (Differential input)
      Counter Input Channels 4
      Trigger Input Channels 1

    ANALOG CHANNELS

    • High or low speed data acquisition
    • Self-calibrating for ratiometric transducers
    • 8th order, linear phase, anti-aliasing filter
    • Programmable transducer excitation of 5 or 10 Vdc
    • Indefinite short circuit protection
    • Independent input range (Gain) for each channel
    • Independent zero-offset voltage for each channel

    Input Ranges:

      • Gain = 1000 ± 2.500 mV
      • Gain = 100 ± 25.00 mV
      • Gain = 10 ± 250.0 mV
      • Gain = 1 ± 2.500 V

      Post-Gain Channel Offset Range: ± 2.50 V
      Data Resolution 0.024% of full scale
      Data Accuracy (min) 0.195% of full scale
      • (Includes all internal noise & temperature drift)
      Lowpass Filter Range (Fc) 0.45 - 14,750 Hz
      • (The programmed Fc is common to all 8 channels)
      Input Impedance (typical) 1.0 M Ohm
      Protected Input Range (max) ± 25.0 V
      Transducer Excitation Drive (per 4 channel group)
      125 mA @ 10 Vdc 65 mA @ 5 Vdc

    COUNTER CHANNELS

    • Low speed data acquisition only
    • Counters are sampled without affecting the count
    • 14 bits of resolution
    • Internal 2 bit prescaler for extended count range
    • 5 Vdc digital transducer excitation
    • Extended input range protection
      Positive Going Threshold (min) 3.0 Vdc
      Negative Going Threshold (min) 0.7 Vdc
      Hysteresis (min) 1.0 Vdc
      Digital Excitation Drive (max) 90 mA
      Protected Input Range (max) ± 25.0 V

    TRIGGER CHANNEL

      Three Trigger Options:
      • One shot data acquisition with pre-trigger samples
      • Multi-trigger data acquisition with a fixed number of samples taken for each trigger event
      • Level sensitive trigger - data taken as long as the trigger input level is high
      Programmable trigger state (NO or NC)
      Positive Going Threshold (min) 3.0 Vdc
      Negative Going Threshold (min) 0.7 Vdc
      Hysteresis (min) 1.0 Vdc
      Protected Input Range (max) ± 25.0 V

    REAL TIME CLOCK

      Year, month, day, hours, minutes, and seconds
      ± 5 minutes/month accuracy
      Date and time stamp for each triggered data acquisition cycle

    COMMUNICATIONS

      High speed RS-232-C serial port
      Baud rates: 9600, 19.2K, 38.4K, 57.6K, 115.2K

    POWER SUPPLY

      Protected against voltage surges common to automotive alternator systems
      Wide input voltage range
      Indefinite reverse polarity protection
      Supply Voltage Range 10.0 - 17.0 Vdc
      Protected Supply Voltage Range ± 25.0 Vdc
      Data BRICK Power Requirements (@ 25 °C) 4.8 W
      plus (1.5 x transducer excitation load [amps]) W

    HOST COMPUTER SOFTWARE

    • Available for PC compatible DOS computers
    • VGA graphics support
    • Graphical, Menu Driven Features Include:
      • Data BRICK setup screens
      • Real time data acquisition screens
      • Auto calibration functions
      • Data reduction and display screens
      • Single, overlay and cross plots
      • ASCII data file support
    • High speed serial communications

    PHYSICAL

      6061 T6 Machined aluminum enclosure
      6" x 4" x 2.3" (15.2 cm x 10.2 cm x 5.8 cm)
      (excluding the mounting flange)
      2.86 lb. (1.3 Kg), w/o battery
      Rugged, latching connectors
      Splash resistant enclosure and connectors

    ENVIRONMENTAL

      Operating Temperature Range 32 to 140°F (0 to 60°C)
      Operating Humidity Range 0 to 95 % RH
      Operating Shock Loading 100 g, 30 msec (half-sine equivalent, any orientation)

* Specifications subject to change without notice

Description Applications Specifications Accessories Return to Products
GMH

About GMH Home Products Services Literature Site Map Contact Us
Copyright (c) 2003 GMH Engineering - Conditions of Use